川消干粉滅火系統組件部分安裝介紹
來源:http://m.xintli.net/ 日期:2022-06-06
干粉滅火系統的安裝應在相應的技術標準、質量管理體系和施工質量檢驗制度下進行,并對施工全過程進行質量控制。下面來介紹下干粉滅火系統組件部分安裝相關內容。
The dry powder fire extinguishing system shall be installed under the corresponding technical standards, quality management system and construction quality inspection system, and the whole construction process shall be subject to quality control. The following describes the installation of components of the lower dry powder fire extinguishing system.
干粉儲存容器
Dry powder storage container
干粉儲存容器在安裝前需核對其安裝位置符合設計圖紙要求,周邊要留操作空間及維修間距;干粉儲存容器的支座應與地面固定,并做防腐處理;且安裝地點避免潮濕或高溫環境,不受陽光直接照射。
Before installation, the dry powder storage container shall be checked that its installation position meets the requirements of the design drawings, and the surrounding shall be reserved with operation space and maintenance space; The support of the dry powder storage container shall be fixed with the ground and shall be subject to anti-corrosion treatment; In addition, the installation site shall be protected from humid or high-temperature environment and direct sunlight.
在安裝時,要注意防護裝置的泄壓方向不能朝向操作面;壓力顯示裝置方便人員觀察和操作;閥門便于手動操作。
During installation, it shall be noted that the pressure relief direction of the safety protection device shall not face the operating surface; The pressure display device is convenient for personnel to observe and operate; The valve is easy to operate manually.

驅動氣體儲瓶
Drive gas reservoir
驅動氣體儲瓶在安裝前要檢查瓶架是否固定牢固并做了防腐處理;檢查集流管和驅動氣體管道內腔,確保清潔無異物并堅固在瓶架上。
Before installation of the driving gas storage bottle, check whether the bottle rack is fixed firmly and has been subject to anti-corrosion treatment; Check the inner cavity of the collecting pipe and the driving gas pipe to ensure that they are clean, free of foreign matters and firmly fixed on the bottle rack.
安裝驅動氣體儲瓶時,注意防護裝置的泄壓方向不能朝向操作面;啟動氣體儲瓶和驅動氣體儲瓶上壓力計、檢漏裝置的安裝位置便于人員觀察和操作;驅動介質流動方向與減壓閥、止回閥標記的方向一致。
When installing the drive gas storage bottle, pay attention that the pressure relief direction of the safety protection device cannot face the operating surface; The installation positions of the pressure gauge and leak detection device on the start-up gas cylinder and the drive gas cylinder are convenient for personnel to observe and operate; The flow direction of the driving medium is consistent with the direction marked on the pressure reducing valve and check valve.
干粉輸送管道
Dry powder conveying pipeline
川消干粉輸送管道在安裝前需清潔管道內部,避免油、水、泥沙或異物存留管道內,其安裝時應注意以下幾點:
Before the installation of Chuanxiao dry powder transmission pipeline, the inside of the pipeline shall be cleaned to avoid oil, water, sediment or foreign matters in the pipeline. The following points shall be paid attention to during the installation:
1.采用螺紋連接時,管材采用機械切割;螺紋不得有缺紋和斷紋等現象;螺紋連接的密封材料均勻附著在管道的螺紋部分,擰緊螺紋時,避免將填料擠入管道內;安裝后的螺紋根部有2~3扣外露螺紋,連接處外部清理干凈并做防腐處理。
1. when threaded connection is adopted, the pipe shall be mechanically cut; The thread shall be free of flaws and broken lines; The sealing material of threaded connection is uniformly attached to the threaded part of the pipe. When tightening the thread, avoid squeezing the filler into the pipe; After installation, there are 2~3 exposed threads at the root of the thread, and the outside of the joint is cleaned and treated with anti-corrosion treatment.
2.采用法蘭連接時,襯墊不能凸入管內,其外邊緣宜接近螺栓孔,不能放雙墊或偏墊。擰緊后,凸出螺母的長度不能大于螺桿直徑的1/2,確保有不少于2扣外露螺紋。等等。
2. when flange connection is adopted, the gasket shall not protrude into the pipe, its outer edge shall be close to the bolt hole, and double gaskets or partial gaskets shall not be placed. After tightening, the length of the protruding nut shall not be greater than 1/2 of the screw diameter to ensure that there are not less than 2 exposed threads. wait.
在系統組件安裝完成后,還需由建設單位組織委托相應資質的消防設施檢測機構進行檢測,以判斷系統安裝是否符合相關技術標準。更多相關內容就來我們網站
m.xintli.net進行咨詢了解吧!
After the installation of system components is completed, the construction unit shall also organize and entrust a qualified fire-fighting facility testing institution to conduct testing to determine whether the system installation meets the relevant technical standards. For more information, please visit our website at www.cx-fire Www. 68mn. Com!