川消室內消火栓箱內應配置這幾樣東西
來源:http://m.xintli.net/ 日期:2022-07-21
室內消火栓是用于撲滅建筑物初期火災的消防設施,也是我們常見的消防設施之一。那么室內消火栓箱內一般應配置什么呢?實際上消火栓箱是放置消火栓及其附件的場所,一般放置以下設施、設備和器材。
Indoor fire hydrant is a fire-fighting facility used to extinguish the initial fire of buildings, and it is also one of our common fire-fighting facilities. So what should be configured in the indoor fire hydrant box? In fact, the fire hydrant box is the place where the fire hydrant and its accessories are placed. Generally, the following facilities, equipment and apparatus are placed.
1、消防給水管道與消火栓接口
1. Interface between fire water supply pipeline and fire hydrant
室內消防給水管道鋪設在消火栓箱內,并與消火栓箱內的消火栓接口連接。消火栓接口中心要求離地1.1米,要求消火栓接口垂直于墻面或平行于墻面。插口不得影響消火栓箱門的操作和關閉,插口直徑為65mm;
The indoor fire water supply pipeline is laid in the fire hydrant box and connected with the fire hydrant interface in the fire hydrant box. The center of the fire hydrant interface is required to be 1.1m above the ground, and the fire hydrant interface is required to be perpendicular to or parallel to the wall. The socket shall not affect the operation and closing of the fire hydrant box door, and the socket diameter is 65mm;

2.消防水帶和消防槍
2. Fire hose and fire gun
消火栓箱一般配有消防水帶和消防水槍。要求軟管不得與箱底接觸放置,以免水軟管吸收空氣中的水分而腐爛。同時,軟管的長度不應大于25米。;需要配置的水槍噴嘴直徑不小于19mm;
Fire hydrant boxes are generally equipped with fire hoses and fire water guns. It is required that the hose shall not be placed in contact with the bottom of the box, so as to prevent the water hose from absorbing moisture in the air and rotting. At the same time, the length of the hose should not be greater than 25 meters.; The diameter of the water gun nozzle to be configured shall not be less than 19mm;
3.消防水帶卷盤
3. Fire hose reel
在一些建筑物中,由于規范要求,必須安裝消防水帶卷盤,而消防水帶卷盤一般安裝在消火栓箱內。
川消小編提醒您,不得小于19mm,螺栓開口直徑應為25mm,軟管卷盤管口直徑不得小于6mm;
In some buildings, due to the requirements of the specification, the fire hose reel must be installed, and the fire hose reel is generally installed in the fire hydrant box. Chuanxiao Xiaobian reminds you that it should not be less than 19mm, the diameter of bolt opening should be 25mm, and the diameter of hose reel nozzle should not be less than 6mm;
4.滅火器
4. Fire extinguisher
有的消火栓箱分為上下兩部分。消防栓及其附件放在上面,滅火器放在下面。一般建筑物內的火災種類有A類火災、B類火災或C類火災,所以配置ABC干粉滅火器是適用的。1點應配置的滅火器數量由計算確定,但一個配置點配置的滅火器數量不得少于2個,不超過5個。
Some fire hydrant boxes are divided into upper and lower parts. The fire hydrant and its accessories are placed on the top, and the fire extinguisher is placed below. Generally, the fire types in buildings include class a fire, class B fire or class C fire, so it is applicable to configure ABC dry powder fire extinguishers. The number of fire extinguishers that should be configured at one point is determined by calculation, but the number of fire extinguishers configured at one configuration point should not be less than 2 and not more than 5.
以上就是關于室內消火栓箱內應配置這幾樣東西的全部內容,希望對大家有所幫助。對于我們生活中的消防設備,必須定期進行檢查,防止出現損壞或是老化等現象。想了解更多相關內容,請繼續關注我們
http://m.xintli.net!
The above is all about the configuration of these things in the indoor fire hydrant box. I hope it will help you. The fire-fighting equipment in our life must be checked regularly to prevent damage or aging. For more information, please continue to follow us http://m.xintli.net !