消防泵安裝的具體步驟內(nèi)容
來源:http://m.xintli.net/ 日期:2022-07-26
消防泵說白了,消防上放的泵,但對(duì)消防事業(yè)很是重要,所以說全部日常的維護(hù)保養(yǎng)與養(yǎng)護(hù)也是不可有違的。那么消防泵安裝的具體步驟是怎樣的?
Fire pump to put it bluntly, fire safety on the pump, but it is very important to the fire cause, so all the daily maintenance and maintenance can not be violated. What are the specific steps of fire pump installation?
1、消防泵安裝前應(yīng)檢查產(chǎn)品合格證的強(qiáng)度,其規(guī)格、型號(hào)、規(guī)格、功能應(yīng)符合設(shè)計(jì)規(guī)定,并按安裝說明書進(jìn)行安裝;
1. Before the installation of the fire pump, the strength of the product certificate shall be checked, and its specification, model, specification and function shall comply with the design regulations, and the installation shall be carried out according to the installation instructions;
2、消防泵安裝前,應(yīng)檢查離心泵基礎(chǔ)混凝土的強(qiáng)度、減振裝置、坐標(biāo)、設(shè)計(jì)標(biāo)高、地腳螺栓孔的規(guī)格及位置;
2. Before the installation of the fire pump, the strength of the foundation concrete of the centrifugal pump, the damping device, the coordinates, the design elevation, and the specification and position of the anchor bolt hole should be checked;
3、安裝消防泵前,川消小編建議您應(yīng)檢查消防泵的中部,以及消防泵與墻壁或其他設(shè)施的間距,并應(yīng)符合安裝、運(yùn)行和防護(hù)監(jiān)督的要求;
3. Before installing the fire pump, Chuanxiao Xiaobian suggests that you should check the middle of the fire pump and the distance between the fire pump and the wall or other facilities, and should meet the requirements of installation, operation and protection supervision;
4、消防泵吸濕管上的調(diào)節(jié)閥應(yīng)在消防泵固定在底座后安裝。其直徑不應(yīng)小于消防泵吸濕口的直徑,不應(yīng)使用無可靠鎖緊裝置的調(diào)節(jié)閥。宜選用溝式或?qū)A式止回閥閘閥;
4. The regulating valve on the hygroscopic pipe of the fire pump shall be installed after the fire pump is fixed on the base. Its diameter should not be less than the diameter of the hygroscopic port of the fire pump, and the regulating valve without a reliable locking device should not be used. Groove or wafer check valve gate valve should be selected;

5、當(dāng)消防泵和消防水庫位于兩個(gè)獨(dú)立的底座并相互剛性連接時(shí),吸濕管應(yīng)配備柔性連接管;
5. When the fire pump and the fire reservoir are located on two independent bases and rigidly connected with each other, the moisture absorption pipe shall be equipped with flexible connecting pipe;
6、吸濕管水平管段不應(yīng)有氣體和蒸汽泄漏。大小頭連接時(shí),應(yīng)選用偏心異徑管件,并沖洗管頂;
6. There should be no gas and steam leakage in the horizontal pipe section of the moisture absorption pipe. When connecting large and small heads, eccentric reducing pipe fittings should be selected, and the pipe top should be flushed;
7、消防泵出水口應(yīng)安裝消聲止回閥、調(diào)節(jié)閥和氣壓表;系統(tǒng)軟件主出水口還應(yīng)安裝氣壓表和壓力控制器;安裝氣壓表時(shí)應(yīng)加緩沖裝置。氣壓表與緩沖裝置之間應(yīng)安裝旋塞閥;如果設(shè)計(jì)方案中沒有規(guī)定壓力表的量程,則應(yīng)為系統(tǒng)軟件壓力的2倍左右;
7. Silencing check valve, regulating valve and barometer shall be installed at the outlet of fire pump; The main water outlet of the system software shall also be equipped with a barometer and a pressure controller; Buffer device shall be added when installing barometer. A plug valve should be installed between the barometer and the buffer device; If the range of the pressure gauge is not specified in the design scheme, it should be about twice the pressure of the system software;
8、
川消消防泵減振裝置及進(jìn)水口軟接頭的安裝應(yīng)符合設(shè)計(jì)要求,并應(yīng)有產(chǎn)品介紹及安裝說明。
8. The installation of vibration damping device and water inlet soft joint of Chuanxiao fire pump shall meet the design requirements, and there shall be product introduction and installation instructions.
消防泵廣泛運(yùn)用于環(huán)境保護(hù)、污水處理、消防等單位,而其種類都相似的,僅僅一致和數(shù)據(jù)流量有不一樣,所以消防泵在安裝時(shí)要符合規(guī)定,以上就是相關(guān)內(nèi)容了,有疑問就來關(guān)注網(wǎng)站
http://m.xintli.net聯(lián)系我們吧!
Fire pumps are widely used in environmental protection, sewage treatment, fire safety and other units, and their types are similar, only consistent and different from the data flow, so the installation of fire pumps should comply with the regulations. The above is the relevant content. If you have any questions, please pay attention to the website http://m.xintli.net Contact us!