川消氣體滅火系統問題怎么處理?
來源:http://m.xintli.net/ 日期:2022-09-02
川消氣體滅火系統主要用在不適于設置水滅火系統等其他滅火系統的環境中,比如計算機機房、重要的圖書館檔案館、移動通信基站(房)、UPS室、電池室、一般的柴油發電機房等。那么氣體滅火系統問題怎么處理?與小編一起來看看吧。
Chuanxiao gas fire extinguishing system is mainly used in the environment where water fire extinguishing system and other fire extinguishing systems are not suitable, such as computer room, important library and archives, mobile communication base station (room), UPS room, battery room, general diesel generator room, etc. How to deal with the problem of gas fire extinguishing system? Let's have a look with Xiaobian.
1、施工隊不能提供氣體輸送管的試壓數據,只是口頭上告知試過壓了,具體是何時試壓?試壓人員是誰?都無法提供。所以是否試過壓只能是個問號。
1. The construction team can't provide the pressure test data of the gas transmission pipe, but only tells verbally that the pressure test is excessive. When is the pressure test? Who is the pressure tester? Could not provide. Therefore, whether to test overvoltage can only be a question mark.
2、申請調試前施工操作人員對產品不作細致的了解。結果調試時出現聲光報警不動作,報警點無法打印。要其整改時反而提出用備用電池時是不能打印的論點。咨詢了生產廠家后才得到無其之說的結論。
2. Before applying for commissioning, the construction operators do not have a detailed understanding of the product. Results the audible and visual alarm did not act during debugging, and the alarm point could not be printed. When they were asked to rectify, they argued that they could not print when using backup batteries. After consulting the manufacturer, we came to a conclusion without explanation.
3、對氣體滅火的性質了解不到位。防護區的門窗只是用一般性的材料和玻璃。在施工中不能提出異議,到調試驗收中才發現該問題為時已晚,特別是防護區的門應是能自動關閉的也不清楚,也就太不應該了。
3. The nature of gas fire extinguishing is not well understood. Doors and windows in the protection area are only made of general materials and glass. We can't raise any objection during construction. It's too late to find out the problem until commissioning and acceptance. In particular, it's not clear whether the door of the protection area can be closed automatically, which is too inappropriate.

4、氣體儲存室與配電間合用,這是不許可的。儲存室的通道、應急照明、門、窗的防火等級、開啟方向和儲存室的排風裝置關系到人身應予重視。
4. It is not allowed to share the gas storage room with the power distribution room. The passageway, emergency lighting, fire rating and opening direction of doors and windows of the storage room and the exhaust device of the storage room are related to personal safety and should be paid attention to.
氣體滅火系統一般由瓶組、選擇閥、噴頭、單向閥、集流管、連接管、泄放裝置、驅動裝置、檢漏裝置、信號反饋裝置、低泄高封閥、管路管件等部件構成,在使用中免不了會有問題存在,您要提前了解好避免掉。更多事項就來我們網站
http://m.xintli.net一起了解吧!
The gas fire extinguishing system is generally composed of cylinder group, selector valve, spray nozzle, one-way valve, manifold, connecting pipe, safety relief device, drive device, leakage detection device, signal feedback device, low discharge and high seal valve, pipeline fittings and other components. Problems are inevitable in use. You should know in advance to avoid them. Come to our website for more information http://m.xintli.net Let's get to know each other!