關(guān)于消防泵的維護和檢查內(nèi)容
來源:http://m.xintli.net/ 日期:2022-09-24
任何機械設(shè)備的使用都是需要進行定期的維護和保養(yǎng)的,這也包括我們的消防泵,那么對于它的保養(yǎng)內(nèi)容該如何進行呢?下面
川消小編為您解答。
The use of any mechanical equipment requires regular maintenance, which also includes our fire pump. How to carry out its maintenance? Now, let's answer for you.
我們應(yīng)該檢查泵房、散熱通風(fēng)等設(shè)備、包括百葉窗,我們需要保證泵房內(nèi)是有比較好的散熱條件的;我們還需要檢查各個閥門的開啟狀態(tài),確保各個閥門都是處在正常的工作狀態(tài)下的,我們還需要確保進出水管能夠正常的工作,確保動力部分和水泵連接是牢固的,另外我們還需要確保控制器以及各個部分都是正常工作的,確保柴油引擎系統(tǒng)是不是能正常工作。
We should check the pump room, heat dissipation and ventilation equipment, including shutters. We need to ensure that there is good heat dissipation conditions in the pump room; We also need to check the opening state of each valve to ensure that each valve is in normal working condition. We also need to ensure that the water inlet and outlet pipes can work normally, and that the power part and water pump are firmly connected. In addition, we need to ensure that the controller and all parts are working properly to ensure that the diesel engine system can work normally.
我們還需要每周對消防泵進行檢查,包括它的備用電源是不是切換正常,看看它是否能夠保證在三十秒內(nèi)使得水泵投入正常的運行,我們還需要檢查備用的水泵能不能自動切換投入運行當(dāng)中。
We also need to check the fire pump every week, including whether its standby power supply can be switched normally, to see whether it can ensure that the pump can be put into normal operation within 30 seconds, and we also need to check whether the standby pump can be automatically switched into operation.
我們還需要檢查水管路上的閘閥、止回閥、水錘裝置是不是正常的,這些設(shè)備的檢查其實都是非常需要的,這也是保證我們的消防泵能否后期工作順利的一個保障。
We also need to check whether the gate valve, check valve and water hammer elimination device on the water pipe are normal. In fact, the inspection of these equipment is very necessary, which is also a guarantee to ensure that our fire pump can work smoothly in the later period.

保護保養(yǎng)方法
Protection and maintenance methods
(1)每周消防水泵少運轉(zhuǎn)一次,運轉(zhuǎn)時刻電動泵不少于10min、柴油泵發(fā)動不少于30min,查看水泵的出水壓力是否符合要求。
(1) The fire pump shall be operated less once a week. The electric pump shall be operated for at least 10min, and the diesel pump shall be started for at least 30min. Check whether the water outlet pressure of the pump meets the requirements.
(2)每周消防水泵運轉(zhuǎn)前,查看泵組是否無缺。要求:
(2) Check whether the pump unit is intact before the fire pump runs every week. requirement:
①泵的吸水、出手、旁通管能悉數(shù)開放;
① The suction, discharge and bypass pipes of the pump can be fully opened;
②泵組無泄漏;
② The pump unit has no leakage;
③進、出管壓力表正常;
③ The inlet and outlet pipe pressure gauges are normal;
④消防水池儲滿消防用水。
④ The fire pool is full of fire water.
(3)每周消防水泵運轉(zhuǎn)前,查看電器操控部分是否無缺。
(3) Before the fire water pump runs every week, check whether the electrical control part is intact.
要求:
requirement:
①電源開關(guān)指示正指示燈正常;
① The positive indicator of the power switch is normal;
②切換、轉(zhuǎn)化指示燈正常;
② The switching and conversion indicators are normal;
③備電發(fā)動、阻隔開關(guān)封閉;
③ Standby power starting and blocking switch closing;
④報警反饋信號指示燈不亮、正常指示燈敞開。
④ The alarm feedback signal indicator is not on, and the normal indicator is open.
(4)每周消防水泵運轉(zhuǎn)前,查看主、備電源切換正常,查看備用電源,看能否確保在30s內(nèi)使水泵投入正常運轉(zhuǎn);檢杳備用水泵能否自動切換投入運轉(zhuǎn)。
(4) Before the operation of the fire water pump every week, check whether the main and standby power switches normally and whether the standby power can ensure the normal operation of the water pump within 30s; Check whether the standby water pump can be switched into operation automatically.
(5)查看出水管路上的閘閥、止回閥、水錘設(shè)備是否正常。
(5) Check whether the gate valve, check valve and water hammer elimination equipment on the outlet pipe are normal.
(6)吸水管人口處的雜物,防止阻塞。
(6) Remove the sundries at the inlet of the suction pipe to prevent blocking.
(7)打開末端試水設(shè)備或消火栓放水,查看水泵能否正常發(fā)動。
(7) Open the end water testing equipment or fire hydrant to drain water and check whether the water pump can be started normally.
以上就是關(guān)于消防泵的維護和檢查內(nèi)容,希望小編的文章可以給到大家一些幫助以及參考的價值,如果有需要訂購消防泵的客戶可以直接與我司
http://m.xintli.net聯(lián)系。
The above is about the maintenance and inspection of the fire pump. I hope that the article can give you some help and reference value. If you need to order a fire pump, you can directly contact our company http://m.xintli.net Contact.