川消泡沫消栓的七點安裝要求
來源:http://m.xintli.net/ 日期:2022-10-07
泡沫消火栓一般都安裝在漏天場所,常年愛日曬雨淋,外表涂漆日久易遭剝蝕、脫落、導致外表生銹,因此要定期檢修,以延長使用壽命。下面來講講
川消泡沫消火栓的七點安裝要求。
Foam fire hydrants are generally installed in places with leaks. They are always exposed to the sun and rain. The surface is easy to be peeled, peeled off and rust after being painted for a long time. Therefore, regular maintenance is required to extend the service life. Next, we will talk about the seven point installation requirements of Chuanxiao foam fire hydrant.
1)一般情況下,室外管道選用地上式泡沫消火栓或地下式泡沫消火栓,室內管道選用室內泡沫消火栓或消火栓箱。
1) Generally, the outdoor pipeline shall use the ground foam fire hydrant or underground foam fire hydrant, and the indoor pipeline shall use the indoor foam fire hydrant or fire hydrant box.
2)地上式泡沫消火栓要垂直安裝,地下式泡沫消火栓要安裝在消火栓井內的泡沫混合液管道上。
2) The above ground foam fire hydrant shall be installed vertically, and the underground foam fire hydrant shall be installed on the foam mixture pipeline in the fire hydrant well.
3)地上式泡沫消火栓的大口徑出液口要朝向消防車道,以便于消防車或其他移動式的消防設備吸液口的安裝。地上式泡沫消火栓上的大口徑出液口,在一般情況下不用,而是利用其小口徑出液口即KWS65型接口,接上消防水帶和泡沫槍進行滅火,當需要利用消防車或其他移動式消防設備滅火,而且需要從泡沫混合液管道上設置的消火栓上取用泡沫混合液時,才使用大口徑出液口。
3) The large diameter liquid outlet of the ground foam fire hydrant shall face the fire lane, so as to facilitate the installation of the liquid suction port of the fire truck or other mobile fire-fighting equipment. The large diameter liquid outlet on the ground foam fire hydrant is not used under normal circumstances, but its small diameter liquid outlet, namely KWS65 type interface, is used to connect the fire hose and foam gun to extinguish the fire. The large diameter liquid outlet is only used when the fire truck or other mobile fire-fighting equipment is required to extinguish the fire, and the foam mixture is required to be taken from the fire hydrant set on the foam mixture pipeline.

4)地下式泡沫消火栓要有明顯長久性標志,一般在井蓋上都有標志,但由于銹蝕或被灰塵覆蓋,甚違反規(guī)定堆放物資,使得在使用時很難快速找到消火栓,為了可在明顯處設置標志,如在附近的墻上設置標志。
4) Underground foam fire hydrants should have obvious permanent signs, usually on the well cover, but it is difficult to quickly find the fire hydrant in use because of rust or dust cover, or even stacking materials in violation of regulations. For safety, signs can be set at obvious places, such as on the adjacent wall.
5)地下式泡沫消火栓頂部與井蓋底面的距離不得大于0.4m,且不小于井蓋半徑,這樣做是為了消防人員操作快捷方便,以免下井操作,也避免井蓋被乳壞而損壞消火栓。
5) The distance between the top of the underground foam fire hydrant and the bottom of the well cover shall not be more than 0.4m, and shall not be less than the radius of the well cover. This is for the convenience of the fire fighters, so as to avoid the operation in the well and the damage of the well cover to the fire hydrant.
6)室內泡沫消火栓的栓口方向宜向下或與設置泡沫消火栓的墻面成90°,栓口離地面或操作基面的局度一般為1.1m,允許偏差為±20mm,坐標的允許偏差為20mm。
6) The nozzle of indoor foam fire hydrant should be downward or 90 ° to the wall where the foam fire hydrant is installed. The location of the nozzle from the ground or the operating base surface is generally 1.1 m, with the allowable deviation of ± 20 mm and the allowable deviation of coordinates of 20 mm.
7)泡沫泵站內或站外附近泡沫混合液管道上設置的泡沫消火栓,要符合設計要求。
7) The foam fire hydrant set on the foam mixture pipeline inside or near the foam pump station shall meet the design requirements.
川消泡沫消栓的主要部件選用了高耐腐蝕材料、同時主要部件處于油箱內,始終能得到充分的潤滑。長時間不用、不保養(yǎng)也不會銹死、卡住。您可以來我們網站
http://m.xintli.net咨詢了解一番!
The main parts of Chuanxiao foam hydrant are made of high corrosion resistant materials, and the main parts are in the oil tank, which can always be fully lubricated. If it is not used or maintained for a long time, it will not rust or get stuck. You can come to our website http://m.xintli.net Ask and understand!