自動消防水炮使用要注重維護
來源:http://m.xintli.net/ 日期:2022-12-13
自動消防水炮設備可通過監控設備可以觀察到現場的火情和滅火狀況,能自動或手動啟動系統滅火,撲滅后能自動停止噴水,并可重復啟停,是一種新型高能效的大空間滅火產品。
川消小編認為,自動消防水炮使用要注重維護!
The automatic fire monitor equipment can observe the fire situation and fire extinguishing status on site through the monitoring equipment, and can automatically or manually start the system to extinguish the fire. After extinguishing, it can automatically stop spraying water, and can be started and stopped repeatedly. It is a new type of energy-efficient large space fire extinguishing product. Chuanxiao Xiaobian believes that the safe use of automatic fire water monitor should pay attention to maintenance!
安裝在舞臺、演播廳、或可兼作演藝用場所的系統,在演出及排練時,應將控制柜(箱)轉換手動,避免誤動作。待演出、排練結束后恢復到自動控制位。
For systems installed on the stage, studio, or places that can also be used for performing arts, during performance and rehearsal, the control cabinet (box) should be switched to manual to avoid misoperation. After the performance and rehearsal, it will return to the automatic control position.
滅火裝置保護的區域內,如有明火施工作業,電、氣焊作業等,應暫時將系統關閉。
In the area protected by the fire extinguishing device, if there are open fire construction operations, electrical and gas welding operations, the system should be temporarily shut down.
滅火裝置在非火災狀態下報警時,應及時關閉該區滅火裝置及電磁閥電源。查明原因后,再進行供電。
When the fire extinguishing device gives an alarm in a non fire state, the power supply of the fire extinguishing device and solenoid valve in the area shall be turned off in time. Power supply shall be carried out after the cause is found out.
在自動消防水炮保護的區域內應避免具有干擾性質人造光源。如:射燈、金屬鹵鎢燈等高溫高熱燈具。
Artificial light sources with interfering properties shall be avoided in the area protected by automatic fire water monitors. Such as spot lamps, metal halide lamps and other high temperature and high heat lamps.
自動消防水炮系統交付使用后,應在消防控制室內24小時設立值班人員。
After the automatic fire water monitor system is delivered for use, a person on duty shall be set up in the fire control room for 24 hours.

滅火系統根據場所的條件不同,每年少進行一次火災模擬試驗。具體操作如下:將系統設置于手動狀態,將水泵控制柜設置在手動狀態,關閉電磁閥的電源。
Fire simulation test shall be conducted for fire extinguishing system at least once a year according to different conditions of the place. The specific operations are as follows: set the system to manual state, set the water pump control cabinet to manual state, and turn off the power supply of the solenoid valve.
模擬點火實驗,自動消防水炮收到火災信號后,應完成啟動、掃描、定位過程,消防控制中心顯示報警地址或防火分區,輸出啟泵信號。
Simulate the ignition test. After receiving the fire signal, the automatic fire monitor shall complete the starting, scanning and positioning process. The fire control center displays the alarm address or fire compartment and outputs the pump start signal.
自動消防水炮的外置傳感器收到火災信號后,應輸出報警信號,消防控制中心顯示報警地址或防火分區,輸出啟泵信號。
After receiving the fire signal, the external sensor of the automatic fire monitor shall output the alarm signal. The fire control center shall display the alarm address or fire compartment and output the pump start signal.
以上為自動消防水炮的相關知識,希望能夠幫到需要的人。此外維護人員應該定期對滅火系統進行巡檢,發現故障及時與代理商和廠家聯系。更多相關消防設備的使用與維護信息了解,就來關注我們網站
http://m.xintli.net吧!
The above is the relevant knowledge of automatic fire water monitor. I hope it can help those who need it. In addition, the maintenance personnel should conduct regular inspections on the fire extinguishing system, and timely contact the agent and manufacturer for solutions in case of any fault. For more information about the use and maintenance of fire-fighting equipment, please pay attention to our website http://m.xintli.net Come on!