川消報警閥組在使用時避免十個問題存在
來源:http://m.xintli.net/ 日期:2022-12-26
報警閥組是自動噴水滅火系統的關鍵組件之一,規范對報警閥組及其組件的安裝作了規定,今天我們分享
川消報警閥組在使用時避免十個問題存在。
The alarm valve group is one of the key components of the automatic sprinkler system. The specification specifies the installation of the alarm valve group and its components. Today, we share ten problems to avoid when using the Sichuan Fire Alarm Valve Group.
1)雨淋報警閥或預作用報警閥的電磁閥入口處未安裝過濾器,水中雜質會影響電磁閥的啟閉;
1) No filter is installed at the inlet of solenoid valve of deluge alarm valve or pre action alarm valve, and impurities in water will affect the opening and closing of solenoid valve;
2)與其它報警閥并聯安裝的雨淋報警閥或預作用報警閥,其控制腔進水管路入口未安裝止回閥,當報警閥入口水壓產生波動時,可能引起其他雨淋報警閥或預作用報警閥的誤動作;
2) For deluge alarm valve or pre action alarm valve installed in parallel with other alarm valves, check valve is not installed at the inlet of the water inlet pipe of the control chamber. When the water pressure at the inlet of the alarm valve fluctuates, it may cause misoperation of other deluge alarm valves or pre action alarm valves;
3)雨淋報警閥或預作用報警閥組的復位閥,在系統正常運行時設在常開狀態,造成報警閥防復位功能失效,甚還會導致報警閥無法正常開啟,無法供水滅火;
3) The reset valve of deluge alarm valve or pre action alarm valve group is set to the normally open state during the normal operation of the system, which causes the failure of the anti reset function of the alarm valve, and even causes the alarm valve to fail to open normally and cannot supply water for fire fighting;
4)預作用報警閥組配套的空壓機組、空氣維持裝置安裝不符合要求;
4) The installation of air compressor unit and air maintenance device matched with pre action alarm valve group did not meet the requirements;

5)安裝在噴淋保護現場的報警閥組,未設置防護圍欄和警示標志,容易被碰撞甚損壞;
5) The alarm valve group installed at the spraying protection site is not equipped with protective fence and warning signs, which is easy to be collided or even damaged;
6)報警閥組安裝高度太低或太高,操作不方便;報警閥安裝部位室內地面未設置排水設施;
6) The installation height of alarm valve group is too low or too high, which makes operation inconvenient; There is no drainage facility on the indoor ground where the alarm valve is installed;
8)報警閥進出口的控制閥采用普通渦輪蝶閥,且未設置鎖定閥位的鎖具;
8) The control valves at the inlet and outlet of the alarm valve are ordinary turbine butterfly valves, and there is no lock to lock the valve position;
9)自動噴水滅火系統設置2個及以上報警閥組,未采用環狀供水管道;
9) The sprinkler system is equipped with two or more alarm valve groups, and no circular water supply pipeline is used;
10)環狀供水管道上設置的控制閥采用普通渦輪蝶閥,且未設置鎖定閥位的鎖具。
10) The control valve set on the annular water supply pipe adopts the ordinary turbine butterfly valve, and there is no lock to lock the valve position.
When using the Chuanxiao alarm valve group, we have explained ten problems to avoid. If you have any questions or needs, please come to the website http://m.xintli.net Leave a message for consultation!