控制川消七氟丙烷檢測(cè)滅火系統(tǒng)有三種方法
來源:http://m.xintli.net/ 日期:2023-02-17
七氟丙烷檢測(cè)滅火系統(tǒng)工作前提是電磁驅(qū)動(dòng)裝置裝有齒輪,目的是防止運(yùn)輸、安裝、調(diào)試過程中的碰撞、震動(dòng)導(dǎo)致閘門失靈。安裝在現(xiàn)場(chǎng)后,使用前必須拔掉齒輪,否則閥門不會(huì)打開。下面
川消小編來講講控制七氟丙烷檢測(cè)滅火系統(tǒng)有什么方法。
The working premise of heptafluoropropane detection and fire extinguishing system is that the electromagnetic drive device is equipped with gears to prevent collision and vibration during transportation, installation and commissioning from causing gate failure. After installation on site, the safety gear must be pulled out before use, otherwise the valve will not open. Now let's talk about the methods of controlling the heptafluoropropane detection and fire extinguishing system.
1.自動(dòng)控制方法:控制器將控制方法選擇開關(guān)置于“自動(dòng)”位置時(shí),滅火裝置處于自動(dòng)控制狀態(tài)。
1. Automatic control method: When the controller sets the control method selection switch to the "automatic" position, the fire extinguishing device is in automatic control state.
如果只有一個(gè)探測(cè)器發(fā)出火災(zāi)信號(hào),控制器就會(huì)發(fā)出異常的聲音信號(hào),不啟動(dòng)滅火裝置,通知出現(xiàn)異常情況。當(dāng)兩個(gè)探測(cè)器同時(shí)發(fā)出火災(zāi)信號(hào)時(shí),探測(cè)器會(huì)發(fā)出火災(zāi)圣光警報(bào),通知火災(zāi)發(fā)生。向相關(guān)人員撤離現(xiàn)場(chǎng),向控制中心發(fā)送火災(zāi)信號(hào),向控制器發(fā)出聯(lián)動(dòng)指令,關(guān)閉風(fēng)機(jī)、防火閥等聯(lián)動(dòng)設(shè)備,延遲30秒后發(fā)出滅火指令,啟動(dòng)電磁驅(qū)動(dòng)裝置,釋放滅火劑,釋放滅火劑,實(shí)施出入口放氣指示燈為了防止傳感器誤操作引起的滅火劑釋放,或者火災(zāi)小值班人員可以自行消滅,在警報(bào)過程中發(fā)現(xiàn)不需要打開滅火器的情況,或者按手動(dòng)控制箱內(nèi)或控制器的緊急停止按鈕,防止控制器滅火指令的發(fā)生,為了避免滅火器啟動(dòng),避免造成不必要的浪費(fèi)和混亂。
If only one detector sends out a fire signal, the controller will send out an abnormal sound signal, and the fire extinguishing device will not be started to notify the abnormal situation. When two detectors send out fire signals at the same time, the detector will send out a fire holy light alarm to notify the fire. Evacuate relevant personnel from the site, send fire signals to the control center, send linkage commands to the controller, shut down the fan, fire damper and other linkage equipment, send out the fire extinguishing command after a delay of 30 seconds, start the electromagnetic drive device, release the fire extinguishing agent, release the fire extinguishing agent, and implement the vent indicator at the entrance and exit to prevent the release of the fire extinguishing agent caused by the misoperation of the sensor, or the personnel on duty can eliminate the fire by themselves, In the process of alarm, it is found that it is not necessary to open the fire extinguisher, or press the emergency stop button in the manual control box or controller to prevent the occurrence of the controller fire extinguishing command, in order to prevent the fire extinguisher from starting and causing unnecessary waste and confusion.

2.電被動(dòng)控制方法:選擇控制器的控制方法。
2. Electric passive control method: select the control method of the controller.
將開路磁力置于“被動(dòng)”位置時(shí),滅火裝置處于電被動(dòng)控制狀態(tài)。在這種控制方式中,探測(cè)器發(fā)送火災(zāi)信號(hào)時(shí),控制器發(fā)出火災(zāi)聲音警報(bào),但滅火器不啟動(dòng)。工作人員可以按“緊急啟動(dòng)”按鈕啟動(dòng)滅火器來撲滅火災(zāi)。每個(gè)保護(hù)區(qū)入口和控制主機(jī)面板都有緊急啟動(dòng)按鈕。如果確認(rèn)保護(hù)區(qū)著火,可以在入口按緊急啟動(dòng)按鈕,或按控制器面板上的緊急啟動(dòng)按鈕來滅火。
When the open-circuit magnetic force is placed in the "passive" position, the fire extinguishing device is in the electrically passive control state. In this control mode, when the detector sends a fire signal, the controller sends an audible fire alarm, but the fire extinguisher does not start. The staff can press the "emergency start" button to start the fire extinguisher to put out the fire. There are emergency start buttons at the entrance of each protection zone and on the control host panel. If it is confirmed that the protection area is on fire, press the emergency start button at the entrance or press the emergency start button on the controller panel to put out the fire.
3.機(jī)械緊急手動(dòng)控制方法:
3. Mechanical emergency manual control method:
控制系統(tǒng)發(fā)生故障時(shí),通過機(jī)械緊急手動(dòng)啟動(dòng)滅火器滅火。
In case of failure of the control system, the fire extinguisher shall be started manually through mechanical emergency.
控制川消七氟丙烷檢測(cè)滅火系統(tǒng)有三種方法,以上就是針對(duì)問題做出的解答了,您對(duì)此有怎樣的疑惑或者需求,歡迎來我們網(wǎng)站
http://m.xintli.net進(jìn)行了解!
There are three ways to control the fire detection and extinguishing system of Chuanxiao Heptafluoropropane. The above is the answer to the question. What doubts or needs do you have about this? Welcome to our website http://m.xintli.net Get to know!