大空間場所選擇消防水炮滅火系統(tǒng)的規(guī)定
來源:http://m.xintli.net/ 日期:2023-03-06
大空間場所適合安裝消防水炮滅火系統(tǒng),這已經(jīng)在眾多項目工程中得以證明,那么在選型及安裝方面,一直都是大家所關注的幾個點,比如說哪類場所要用多大流量的水炮,哪類場所需要用防爆消防炮等等,具體這些在規(guī)范中有無說明呢?今天
川消小編就來為您講解一番。
Large space places are suitable for installing fire water monitor fire extinguishing system, which has been proved in many project projects. In terms of model selection and installation, we have always been concerned about several points, for example, which kind of places need to use water monitor with large flow, which kind of places need to use explosion-proof fire monitor, and so on. Are these specified in the specification? Today, Sichuan Xiaobian will explain it to you.
在新規(guī)范中,將固定消防炮和自動跟蹤定位射流滅火系統(tǒng)的內容統(tǒng)一規(guī)整在了一起,這樣對于滅火系統(tǒng)的設計有了更為清晰條例的匯總,其中關于大空間場所選擇消防水炮滅火系統(tǒng)的規(guī)定,主要有以下幾個方面。
In the new specification, the contents of the fixed fire monitor and the automatic tracking and positioning jet fire extinguishing system are unified and regulated together, so that the design of the fire extinguishing system has a clearer summary of regulations. Among them, the provisions on the selection of fire water monitor fire extinguishing system in large space mainly include the following aspects.
1、自動消防炮滅火系統(tǒng)中單臺炮的流量,對于民用建筑,不應小于20L/s;對于工業(yè)建筑,不應小于30L/s。
1. The flow of a single monitor in the automatic fire monitor extinguishing system shall not be less than 20L/s for civil buildings; For industrial buildings, it shall not be less than 30L/s.

2、持續(xù)噴水時間不應小于1.0h。
2. The continuous water spraying time shall not be less than 1.0h.
3、系統(tǒng)應具有自動控制、消防控制室手動控制和現(xiàn)場手動控制的啟動方式。消防控制室手動控制和現(xiàn)場手動控制相對于自動控制應具有優(yōu)先權。
3. The system shall have automatic control, manual control in fire control room and on-site manual control. Manual control in fire control room and on-site manual control shall have priority over automatic control.
4、自動消防炮滅火系統(tǒng)和噴射型自動射流滅火系統(tǒng)在自動控制狀態(tài)下,當探測到火源后,應少有2臺滅火裝置對火源掃描定位和少1臺且多2臺滅火裝置自動開啟射流,且射流應能到達火源。
4. The automatic fire monitor fire extinguishing system and the automatic jet fire extinguishing system are under automatic control. When the fire source is detected, at least two fire extinguishing devices should scan and locate the fire source, and at least one and more fire extinguishing devices should automatically start the jet, and the jet should be able to reach the fire source.
5、噴灑型自動射流滅火系統(tǒng)在自動控制狀態(tài)下,當探測到火源后,對應火源探測裝置的滅火裝置應自動開啟射流,且其中應少有一組滅火裝置的射流能到達火源。
5. When the fire source is detected, the fire extinguishing device corresponding to the fire source detection device shall automatically start the jet when the spray type automatic jet fire extinguishing system is under automatic control, and the jet of at least one group of fire extinguishing devices can reach the fire source.
規(guī)范前四條說的都是大家所熟知的消防水炮滅火系統(tǒng),第五條則是對于大空間智能噴頭的規(guī)定,如果有些場所受到高度或者內部結構的影響,不適宜選擇消防水炮滅火系統(tǒng)的話,就可以考慮大空間智能噴頭,這一點在很多的項目工程設計中就有體現(xiàn)。
The first four articles of the specification are all about the well-known fire water monitor fire extinguishing system, and the fifth article is about the provisions of the large-space intelligent sprinkler. If some places are affected by the height or internal structure and it is not suitable to choose the fire water monitor fire extinguishing system, the large-space intelligent sprinkler can be considered, which is reflected in many project engineering designs.
The relevant contents of the regulations on the selection of fire water monitor fire extinguishing system in large space places will be explained here. If you have any doubts or needs about this, please come to our website http://m.xintli.net consulting service