川消大空間滅火裝置電源裝置調試應符合要求
來源:http://m.xintli.net/ 日期:2022-09-05
是大空間滅火裝置能在發生火災時自動探測著火部位,并主動噴水。這種系統需要在建筑內部裝修和系統施工完成后進行系統調試,下面是
川消大空間滅火裝置電源裝置調試內容。
It is a large space fire extinguishing device that can automatically detect the fire position and actively spray water in case of fire. This system needs to be debugged after the interior decoration and system construction of the building are completed. The following is the debugging of the power supply device of the fire extinguishing device in Chuanxiao large space.
1)電源裝置的容量應符合設計和現行有關標準的要求;
1) The capacity of the power supply device shall meet the requirements of the design and current relevant national standards;
2)電源裝置的交流輸入和直流備用輸入(蓄電池組)應能自動切換;
2) The AC input and DC standby input (battery pack) of the power supply device shall be able to switch automatically;
3)電源裝置的交流輸入和直流備用輸入切換時,不應影響大空間智能滅火裝置的工作狀態;
3) When the AC input and DC standby input of the power supply device are switched, the working state of the large space intelligent fire extinguishing device shall not be affected;
4)電源裝置的直流備用輸入(蓄電池組)充放電功能正常。
4) The DC standby input (battery pack) of the power supply device has normal charging and discharging functions.

大空間智能滅火裝置調試應符合下列要求:
Commissioning of large space intelligent fire extinguishing device shall meet the following requirements:
1)大空間智能滅火裝置的調試應逐個進行;
1) Commissioning of large space intelligent fire extinguishing devices shall be carried out one by one;
2)通電后復位狀態、監視狀態正常;
2) Reset status and monitoring status are normal after power on;
3)使系統處于手動狀態,在大空間智能滅火裝置進入監視狀態后,在其保護范圍內,模擬火災發生,待火源穩定燃燒后,在規定的時間內,大空間智能滅火裝置應發出報警、啟動水泵、打開電磁閥等信號。
3) Make the system in manual state. After the large space intelligent fire extinguishing device enters the monitoring state, simulate a fire within its protection range. After the fire source is stably burning, the large space intelligent fire extinguishing device should send out signals such as alarm, start the water pump, open the solenoid valve, etc. within the specified time.
此時使系統變為自動狀態,則水泵應立即啟動、電磁閥應立即打開、噴頭應立即噴水滅火。火源熄滅后,可人工復位大空間智能滅火裝置,使其重新處于監視狀態;
At this time, if the system becomes automatic, the water pump should be started immediately, the solenoid valve should be opened immediately, and the sprinkler should be sprayed immediately. After the fire source is extinguished, the large space intelligent fire extinguishing device can be reset manually to put it back in the monitoring state;
4)大空間智能滅火裝置的大流量噴頭在噴水過程中轉動均勻、靈活。
4) The large flow nozzle of the large space intelligent fire extinguishing device rotates evenly and flexibly during the spraying process.
This is all I have to say about the commissioning of the power supply device of the fire extinguishing device in Chuanxiao large space. If you have any questions, you can always pay attention to us http://m.xintli.net I understand.