高壓二氧化碳滅火系統(tǒng)工作時的動作程序
來源:http://m.xintli.net/ 日期:2023-02-28
高壓二氧化碳?xì)怏w滅火系統(tǒng)主要由二氧化碳儲瓶、容器閥、液流單向閥、高壓軟管、集流管、閥、選擇閥、壓力訊號器、稱重檢漏裝置、啟動瓶、電磁閥、氣路單向閥、噴嘴以及高壓管道、管接件、瓶組架等設(shè)備、零部件和材料組成。下面
川消小編來講講它得動作程序是怎樣的吧。
High-pressure carbon dioxide gas fire extinguishing system is mainly composed of carbon dioxide storage cylinder, container valve, liquid flow check valve, high-pressure hose, collecting pipe, safety valve, selector valve, pressure signal, weighing and leak detection device, starting cylinder, solenoid valve, gas path check valve, nozzle, high-pressure pipeline, pipe fittings, bottle rack and other equipment, parts and materials. Let's talk about its action program What is it.
1、當(dāng)滅火系統(tǒng)的開啟方式置于"自動"狀態(tài):
1. When the opening mode of the fire extinguishing system is in the "automatic" state:
報警控制器在接收到同一區(qū)域內(nèi)相鄰兩只不同類型的火災(zāi)探測器同時發(fā)出的火險信號后,會自動啟動滅火控制器,系統(tǒng)進入噴放前30秒階段。在期間,控制器通過設(shè)在保護區(qū)域內(nèi)外的聲光報警器發(fā)出緊急撤離疏散警報,并聯(lián)動關(guān)閉可能影響滅火效果的有關(guān)設(shè)備(如通風(fēng)機、空調(diào)、防火卷簾等)。結(jié)束,滅火控制器即向相關(guān)的電磁閥發(fā)出啟動信號,打開啟動瓶上的電磁閥,釋放出來的高壓啟動氣體打開相應(yīng)的選擇閥和二氧化碳儲瓶容器閥,儲瓶內(nèi)的二氧化碳滅火劑經(jīng)管網(wǎng)和噴嘴噴放到火災(zāi)區(qū)域或保護對象上,實施滅火。
After receiving the fire danger signals sent by two adjacent fire detectors of different types in the same area at the same time, the alarm controller will automatically start the fire extinguishing controller, and the system will enter the countdown phase of 30 seconds before spraying. During the countdown, the controller sends out the emergency evacuation alarm through the audible and visual alarm set inside and outside the protection area, and closes the related equipment (such as ventilator, air conditioner, fire shutter, etc.) that may affect the fire extinguishing effect. At the end of the countdown, the fire extinguishing controller will send a start signal to the relevant solenoid valve, open the solenoid valve on the starting cylinder, open the corresponding selector valve and the carbon dioxide cylinder container valve of the released high-pressure starting gas, and the carbon dioxide extinguishing agent in the cylinder will be sprayed onto the fire area or protected object through the pipe network and nozzle to put out the fire.

2、當(dāng)滅火系統(tǒng)的開啟方式置于"手動"狀態(tài):
2. When the opening mode of the fire extinguishing system is in the "manual" state:
火災(zāi)探測器的動作只會引起火災(zāi)報警,不能使二氧化碳自動噴放。需要由區(qū)域內(nèi)外的工作人員用手按動緊急啟動按鈕,才能啟動二氧化碳滅火系統(tǒng)進行滅火。
The action of the fire detector will only cause the fire alarm, and can not cause the automatic emission of carbon dioxide. It is necessary for staff inside and outside the area to press the emergency start button manually to start the carbon dioxide fire extinguishing system to put out the fire.
3、在自動和手動失靈的情況下:
3. In case of automatic and manual failure:
操作人員還可以采用機械應(yīng)急啟動方式進行啟動滅火。
The operator can also use the mechanical emergency start mode to start the fire fighting.
此外系統(tǒng)根據(jù)使用要求,可組成單元獨立滅火系統(tǒng)、組合分配滅火系統(tǒng),同時可適用于全淹沒保護滅火和局部保護滅火。該系列產(chǎn)品具有功能完善、工作準(zhǔn)確可靠、操作維修方便等特點。可廣泛適用于易燃液體儲存區(qū)、機械設(shè)備易于失火的重要部位、計算機及電子設(shè)備間、圖書館、檔案館、珍品庫、變配電室、飛機汽車庫、廚房及排煙管道等防護區(qū)。您有需求就來咨詢我們
http://m.xintli.net吧!
In addition, the system can form a unit independent fire extinguishing system and a combined distribution fire extinguishing system according to the use requirements, and it can also be used for total flooding protection fire extinguishing and local protection fire extinguishing. This series of products has the characteristics of complete functions, accurate and reliable work, convenient operation and maintenance, etc. It can be widely used in flammable liquid storage area, important parts of mechanical equipment prone to fire, computer and electronic equipment room, library, archives, treasure store, power transformation and distribution room, aircraft garage, kitchen, smoke exhaust pipe and other protection areas. If you have any need, please consult us http://m.xintli.net Come on!